The final compliance deadline for existing homes
North Lakes follows the Queensland-wide requirements. The law applies to existing houses, townhouses and units throughout the suburb.
What a compliant smoke alarm system requires
A few older alarms in the hallway may not be enough. Compliance depends on the alarm type, age, power source, interconnection and placement.
Photoelectric alarms
The alarms must be photoelectric and comply with Australian Standard AS 3786–2014.
Inside every bedroom
Each bedroom needs its own compliant alarm. Hallway-only systems may need additional alarms.
Connecting areas
Hallways or areas connecting bedrooms with the rest of the home also need an alarm.
All interconnected
When one alarm detects smoke, every interconnected alarm in the dwelling must sound.
Where do alarms need to go?
- ✓Inside every bedroom.
- ✓In hallways connecting bedrooms with the rest of the home.
- ✓If there is no hallway, between the bedrooms and the rest of that storey.
- ✓On a storey without bedrooms, in the most likely exit path.
Installation clearances matter
Where practicable, alarms are installed on the ceiling. They should not be installed within:
- 300 mm of a ceiling and wall corner
- 300 mm of a light fitting
- 400 mm of an air-conditioning vent
- 400 mm of a ceiling-fan blade
Estimate how many alarms your North Lakes home may need
Answer a few questions about the number of storeys, bedrooms and connecting areas. The result is indicative and can be sent directly with an installation request.
Your home
How many storeys?
Select the closest option.
Your indicative result
Estimated requirement: 0 smoke alarms
Based on the bedrooms, connecting areas and bedroom-free storeys you selected.
Request installation
Send the estimate to Power Bolt
Your estimated alarm count will be attached automatically.
How the estimated alarm count is calculated
The final number depends on the actual layout, but these examples show why bedroom count alone is not enough.
Three-bedroom single-storey home
3 bedroom alarms + 1 shared connecting-area alarm.
Four-bedroom single-storey home
4 bedroom alarms + 1 shared connecting-area alarm.
Four-bedroom two-storey home
4 upstairs bedrooms + 1 upstairs hallway + 1 downstairs exit-path alarm.
Do all smoke alarms need to be hardwired?
No. The right solution depends on the existing system and the work being completed.
When your existing alarms need attention
Owner-occupiers, landlords and sellers
Owner-occupied homes
Existing private homes, townhouses and units must be upgraded by 1 January 2027.
Rental properties
Rental homes already need compliant interconnected photoelectric alarms. The landlord is responsible for compliance.
Properties being sold
A property being sold must meet the interconnected photoelectric smoke alarm requirements before settlement.
North Lakes smoke alarm questions answered
Do I need a smoke alarm inside every bedroom?
How many alarms does a four-bedroom home need?
Does downstairs need an alarm if all bedrooms are upstairs?
Can battery-powered alarms still comply?
Do I need an electrician?
Why does my alarm beep for no obvious reason?
How often should alarms be tested?
How much does installation cost?
Get a clear smoke alarm assessment before the deadline
Use the estimator to calculate an indicative alarm quantity and send the result directly to Power Bolt Electrical for installation.
Official guidance: Queensland Fire Department smoke alarm information and Queensland installation guidance.